Home > Products > Fixum Gas Detectors > Gas Transmitters > Fixum sex in unum Gas detector
Fixum sex in unum Gas detector
  • Fixum sex in unum Gas detectorFixum sex in unum Gas detector
  • Fixum sex in unum Gas detectorFixum sex in unum Gas detector
  • Fixum sex in unum Gas detectorFixum sex in unum Gas detector
  • Fixum sex in unum Gas detectorFixum sex in unum Gas detector

Fixum sex in unum Gas detector

Zetron supplier's MIC-600 Fixed Six in One Gas Detector is used for 24-hour continuous online monitoring of multiple gas concentrations and temperature and humidity measurement, on-site display of concentration and sound and light alarm for exceeding the standard, and remote data transmission. Nos providere Gas detector OEM / ODM servit.

Model:MIC-600

Mitte Inquisitionem

Mic-DC fixum sex-in-unum Gas detector Factory Price


Mic-DC fixum sex in unum Gas detector habet provectus Circuit consilio et maturescere kernel algorithm processui, et adeptus est numerus software opus patents et apparentia patentes, ita generatim in generatione multi-muneris fixum-linea composita, ut a terrores, ut in industria. In Mich-DC potest deprehendere Gas concentration in pipelines, inlustris spatia et atmosphaerica environas, tum Gas Leaks et potest etiam deprehendere puritatem summus concentration una vapores. Et fortis et durabile explosion-probationem armamentis et fluorocarbon pingere superficies curatio processus sunt idoneam ad varii ancipitia locations et corrosive environments cum fortis acidum et alcali et repugnant in X annis.











Vapores ut detecta
Range
Accuratio
Resolutio
RESPONDET TEMPUS T90
Ammonia Gas (NH3)
0-100ppm
<± II% (F.s)
0.01ppm
≤30 seconds
Combustibilis Gas (ex)
0-100% LEL
<± II% (F.s)
0.1% LEL
≤10 seconds
Methane (Ch4)
0-100% Vol
<± II% (F.s)
0.1% Vol
≤10 seconds
Oxygeni Gas (O2)
0-30% Vol
<± II% (F.s)
0.01% Vol
≤10 seconds
NITROGENIUM Gas (N2)
0-100% Vol
<± II% (F.s)
0.01% Vol
≤10 seconds
Hydrogenii sulfide (H2S)
0-100ppm
<± II% (F.s)
0.01ppm
≤30 seconds
Sulphuris dioxide (SO2)
0-100ppm
<± II% (F.s)
0.01ppm
≤30 seconds
Nitric cadmiae (non)
0-100ppm
<± II% (F.s)
0.01ppm
≤30 seconds
NITROGENIUM Dioxide (No2)
0-100ppm
<± II% (F.s)
0.01ppm
≤25 seconds